High Pressure Boilers Water Parameters Above 150Kg Cm2

  • Offshore price : $20000-$100000 Get a quote on the right form
  • Minimum order quantity : 1 set :High Pressure Boilers Water Parameters Above 150Kg Cm2
  • Supply Capacity : 10 units/month :High Pressure Boilers Water Parameters Above 150Kg Cm2
  • Manufacturer/Brand : Fangkuai boiler
  • Port : Anyang
  • payment terms : Letter of Credit, Wire Transfer, VISA

Leave Your Message And Get Price!

I need the quotation of , the fuel is , this capacity is , use for . My Name is , my Email is , my WhatsApp is , Please Send the detail information for me!

Popular products

HOT

θrion Gas Fired Steam Boiler

Capacity:1-20t/h

Rated thermal efficiency: 100-104%

Fixed working pressure: ≤1.6MPa

Applicable fuel:natural gas etc.

consult
HOT

Gas(oil) Fired Integrated Hot Water Boiler

Capacity:0.7-14MW

Rated thermal efficiency:96-98%

Fixed working pressure:≤1.25MPa

Applicable fuel:Natural gas, light oil, etc.

consult
HOT

H6 Gas Fired Hot Water Boiler

Capacity:0.7-2.8Mw

Rated thermal efficiency: 97.2-106%

Fixed working pressure:0.1MPa

Applicable fuel:Natural gas, etc.

consult
HOT

T7 Vacuum Hot Water Boilerr

Capacity:2.8-7.0Mw

Rated thermal efficiency:≥105.5%

Fixed working pressure:-0.02MPa

Applicable fuel:Natural gas, etc.

consult
HOT

V6 Gas Fired Hot Water Boiler

Capacity:99Kw

Rated thermal efficiency:97.2-104.4%

Fixed working pressure:1.0MPa

Applicable fuel:Natural gas, etc.

consult
HOT

Electric Steam Boiler

Capacity:0.5-4.0 t/h

Rated thermal efficiency:98%

Fixed working pressure:≤1.25MPa

Applicable fuel:electric energy

consult

Leave us a message

We will send out plans and quotations within five minutes

Name (optional)

Email

Whatsapp

Choose product type

Message

boilermanufactory

Get display discount

boiler
Contact us

Global Sales Hotline:
0086-371-60922096

Email: [email protected]

Voicemail
  • IBR - 1950 : Reg. 626

    IS: 10496-1983 Indian Standard SPECIFICATION FOR FEED WATER, BOILER WATER AND CONDENSATE FOR HIGH PRESSURE BOILERS 0. FOREWORD 0.1 This Indian Standard was adopted by the Indian Standards Institution on 7 January 1983, after the draft finalized by the Boiler Water SectionalGet Price

  • Power plant and calculations

    Calculate the boiler feed pump and motor size required for a boiler of capacity 90 TPH has steam drum working pressure 88 kg/cm2. The height of the drum is 35 meter from boiler feed pump Centre. And the suction water to pump is taken from Deaerator which is situated 15 meter above the pump centre.Get Price

  • Steam Boilers, Engines, Nozzles and Turbines

    27. The dry saturated steam at very low pressure, (5-10 kg/cm2) when throttled to atmosphere will become (a) wet (b) superheated (c) remain dry satruated (d) dry (e) none of the above. Ans: b 28. Water at pressure of 4 kg/cm2 and 160°C temperature when exposed to atmosphere willGet Price

  • High Pressure Boilers - slideshare.net

    Sep 19, 2012 · High Pressure Boilers 1. HP BOILERS 2. HP BOILERS Sr Parameter OV Unit alarm Sr Parameter OV unit alar no no m 1 Main steam pressure/Drum 85 Kg/cm2 22 Primary SH before Attmpt. 354 0c pressure 23 ESP outlet flue gas 129 0c 2 Main steam temperature 463 0c 3 Drum level 336 Mmwc 24 ESP 1A 20/135 Ma 4 Oxygen 8.56 % 25 ESP 1B 40/160 Ma OPERATING …Get Price

  • (PDF) Steam Boiler - ResearchGate

    These boiler falls under the category of high pressure boiler. The steam generation rate in water tube boiler is high i.e. 450 tonne s per hour. For a given power the floor area required for the Get Price

  • Atmospheric Pressure Boiler 20 Ton Kazakhstan

    high pressure boiler water parameters above 150 kg cm2. High (HP) water limits Limits on water conditions for the limits are TDS = 3500ppm Silica = 150ppm Sulfite - Summary Phosphate for Hardness Feed water 1968 Tons/day = 1968×1000 kg/ 3. Get A QuoteGet Price

  • Boiler water Limit:-

    The following are specified limit for high pressure boiler from BOILER WATER Parameters Upto 20 Kg/cm2 21 Kg/cm2to 39 Kg/cm2 Above 2.5 Above 2.5 Above 2.5 Ratio Na 2SOGet Price

  • Hydraulic transmission feed pumps for steam and hot water

    kgf / cm2. Pumps for water heating boilers with a heating capacity of 4 Gcal / hour (4,65 MW) and more must have two independent power supplies. The pressure that is developed by the circulation and make-up pumps must exclude the possibility …Get Price

  • BOILERS | Energy-Models.com

    Figure 2.3 Water Tube Boiler: Water tube or "water in tube" boilers in which the conditions are reversed with the water passing through the tubes and the hot gasses passing outside the tubes (see figure 2.3). These boilers can be of single- or multiple-drum type. These boilers can be built to any steam capacities and pressures, and have higher efficiencies than fire tube boilers.Get Price

  • China Industrial 150kg/H Biomass Steam Boiler Used for

    Industrial 150Kg/h biomass steam boiler used for Washing and ironing industry Company introduction Qingdao Hiju Machinery Equipment Co.,Ltd. It is specialized in manufacturing A level Boilers, company offer a wide range of products to meet your various needs.The company's main products include: electric steam generator, oil (gas) steam generator,biomass hot water boiler, …Get Price

  • Super critical boiler - SlideShare

    Aug 21, 2014 · Super critical boiler 1. SUPERCRITICAL BOILER SHIVAJI CHOUDHURY 2. What is SUPER CRITICAL The term "supercritical" refers to main steam operating conditions, being above the critical pressure of water (221. bar). Above the critical pressure there is no distinction between steam and water, i.e. above 221. bar, water is a fluid.Get Price

  • high pressure natural gas lpg heavy oil horizontal boiler

    Nov 28, 2020 · high pressure boiler water parameters above 150kg cm2 Price: $1-$99999/set Capacity: 700 – 14000 kw Pressure: 0.8 – 1.0 Mpa Fuel: natural gas, coke oven gas, bio-gas,liquid propane gas, diesel, heavy oil, light oil, crude oil Industries: Petroleum, chemical, chemical fiber, pharmaceutical, textile printing and dyeing, building materials, wood processing, …Get Price

  • IS 10496 (1983): Feed Water, Boiler Water and Condensate

    Chemical Regime in Water Quality Management of High Pressure Boiler …Get Price

  • Boiler – Lafil Global

    THREE PASS OIL/GAS FIRED FULLY AUTOMATIC SMOKE TUBE STEAM BOILER. TECHNICAL SPECIFICATION: i – Type – Horizontal, 3 pass, Fully Wet Back, IBR approved Smoke Tube boiler. ii – Capacity – 1000 Kg/hr to 60000 Kg/hr (F & A 100° C) iii – Working Pressure – Std. 10.5 Kg/cm2 (g), 14.06 Kg/cm2 (g), 17.05 Kg/cm2 (g) and above with water tube design also available.Get Price

  • IS 10496 (1983): Feed Water, Boiler Water and Condensate

    IS: 10496-1983 Indian Standard SPECIFICATION FOR FEED WATER, BOILER WATER AND CONDENSATE FOR HIGH PRESSURE BOILERS 0. FOREWORD 0.1 This Indian Standard was adopted by the Indian Standards Institution on 7 January 1983, after the draft finalized by the Boiler Water SectionalGet Price

  • 3 Types of Circulation In Boiler - Water Treatment Basics

    Nov 15, 2018 · Therefore natural circulation is limited to boiler with drum operating pressure around 175 kg/cm2. #2.Controlled Circulation In Boiler: If the Operating pressure of boiler is between 180 kg/cm2 to 200 kg/cm2 then circulation in boiler is to be assisted with mechanical pumps, to overcome frictional losses.Get Price

  • Chlorine Corrosion in a Low-Power Boiler Fired with

    Jan 05, 2022 · The selection of appropriate heat-resistant materials which are at the same time resistant to atmospheres rich in chlorine and its compounds is one of the most important current construction problems in steel boiler elements when using biomass fuels of agricultural origin. In the research presented here, an area was identified in the furnace of a 10 kW boiler where …Get Price

  • High Pressure Boiler 75kg/cm2 Water Parameters in Sugar Plant

    Chemical Regime in Water Quality Management of High Pressure Boiler …Get Price

  • High Pressure Boiler 75Kgcm2 Water Parameters

    High Pressure Boiler 75kg/cm2 Water Parameters in Sugar Plant 2017522 — Sugar plants, when they go in for cogeneration have to install high pressure boilers of 66ata and above with a definite aim to generate surplus Get Price

  • boiler maximum pressures

    Jan 11, 2020 · Boilers are classified as "high-pressure" or "low-pressure" and "steam boiler" or "hot water boiler." Boilers that operate higher than 15 psig are called "high-pressure" boilers . A hot water boiler, strictly speaking, is not a boiler .Get Price

  • steam boiler Agents 15kg cm2

    Dec 19, 2009 · The guidelines for water quality control of water/steam in boiler plants of 60 kg/cm2 and above are furnished as recommended by many boiler designers. The feed water limits. For drum operating pressure kg/cm2 (g) 61-100, 101-165, and 166-205 with PO4 treatment type of boilers: Hardness, in ppm, has to be nil for all pressures.Get Price

  • High Pressure Steam Boiler Is Measure Ton Cm2

    Chemical Regime in Water Quality Management of High Pressure Boiler …Get Price

  • Part II. Energy Efficiency by Sectors Energy Efficiency in

    Water Tube Boilers Used for high pressure high capacity steam boiler Available in sizes that are far greater than the fire tube design. Up to several million pounds per hour of steam. Able to handle higher pressures up to 5,000psig Recover faster than their firetube cousin Have the ability to reach very high temperaturesGet Price

  • FRONT & REAR WALL BOILER.pptx | N Ox | Combustion

    1. Circulation: In high pressure subcritical natural circulation boiler the qty of water re-circulated is in the range of 5 times the qty of feed water flow. For assisted circulation boilers the ratios vary between 1.5 and 4. For a once through boiler the flow qty is limited to only the feed water flow. 2.Get Price

  • .allindustrialtraining.com

    High ash content will— (i) Increase the handling cost (ii) Causes clinkering and slagging (iii) Reduce boiler capacity (iv) All of the above. For the same diameter and thickness of tube, a water tube boiler compared with a fire tube boiler has size of boiler tube is specified by— (i) Less heating surface (ii) Equal heating surfaceGet Price

  • nebraska boiler company

    Our oil/gas fired boilers can be divided into SZS high pressure boiler water parameters above 150 kg cm2 and WNS high pressure boiler water parameters above 150 kg cm2 depending on the medium inside the tubes. With multiple pressure designs, the water tube boilers can meet the steam supply requirements of 2.5MPa or above. Learn MoreGet Price

  • Boiler Boiler – – Fundamentals Fundamentals and Best

    By: Boiler – Fundamentals and Best Practices Boiler - Fundamentals Steam production and steam uses Steam purity and steam quality Types of boilers Basic boiler principles Basic boiler calculations Steam Production and Steam Uses Steam Production When heat is added to water, its temperature rises at a rate of 0.56°C (1°F) for each heat input of 2.095 kJ/kg (1 Btu/lb) If we …Get Price

  • Boiler Water Treatment for LP,MP and HP Boiler

    Dec 11, 2015 · Anything above 45 Kg/cm2, but practically above 60 Kg/cm2 2. 80 – 120 Kg/cm2 should be treated in a different category 3. Usually combined with extraction or condensing turbine 4. Cogen and CPP are majority, IPP a new category 5.Get Price

  • boiler maximum pressures

    Jan 11, 2020 · Boilers are classified as "high-pressure" or "low-pressure" and "steam boiler" or "hot water boiler." Boilers that operate higher than 15 psig are called "high-pressure" boilers . A hot water boiler, strictly speaking, is not a boiler .Get Price

  • Power plant and calculations: Boiler

    35-A boiler of operating pressure 66 kg/cm2 has LHS water wall panel total length of 25 meters from bottom header to top header, calculate the maximum thermal expansion of panel. Consider the MOC of tube material SA210 Gr.A (Carbon steel) & …Get Price